Loading...
R2024-25 Professional Engineering Services for Replacement of East Alley Wall2024 01-31 Proposal Project No. 03045.193 Page 1 of 8 January 31, 2024 Revised March 7, 2024 Jamie Mount, P.E. Assistant Director of Public Works Village of North Palm Beach 645 Prosperity Farms Rd. North Palm Beach, FL 33408 Via E-Mail: jmount@village-npb.org) RE: Professional Civil Engineering & Surveying Services East Alley Wall Replacement North Palm Beach, Florida Engenuity Group, Inc. Project No. 03045.193 Dear Mr. Mount: We are pleased to offer this proposal to render Professional Civil Engineering & Surveying services in connection with East Alley Wall Replacement in North Palm Beach, FL (hereinafter called the ‘Project’). Surveying Services Engenuity Group, Inc. will prepare a Topographic and Tree Survey pursuant to Chapter 5J-17.050, Florida Administrative Code. The specific survey limits are shown on the graphic below outlined in red from right-of-way to right-of-way for approximately 4,140 Linear Feet. See the attached Designated Scope of Services for a specific list of items to be included on the survey. Additionally, Engenuity Group, Inc will recover sufficient control to establish the right-of-way lines for the alleyway to show on the survey. Surveying Fee: $16,420.00 SUE Services Engenuity Group, Inc. will provide services with due diligence and in a manner consistent with the standards of the subsurface utility locating industry. Every reasonable effort will be made to locate all utility systems of interest whether indicated on record plans available to us or not. However, no guarantee can be made that all existing utility systems can be detected, and or located. Our work to collect as-built drawings and related data from utility companies is crucial for the Project's accuracy and completion. These documents are vital for a thorough representation of subsurface utilities. However, utility companies may not always respond as promptly as we'd like, which could lead to delays. While we strive to DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4 2024 01-31 Proposal Project No. 03045.193 Page 2 of 8 minimize these delays and maintain communication with these companies, their response times and the completeness of their data are beyond our control. The horizontal location effort will include electromagnetic induction, power source detection, and ground penetrating radar (GPR) within the sites. The accuracy of these techniques is subject to the limitation of the available technology and certain factors and field conditions beyond our control. Utility locations are provided for design purposes only in an attempt to prevent or reduce the likelihood of damage during excavation. Areas to be surveyed with GPR must be level, and free of obstructions. Use of this service does not relieve interested parties from their responsibility to make required notifications prior to excavation. Results are dependent upon field conditions at the time of locating services. SUE Fee: $9,324.00 Total Surveying Fee: $25,744.00 Technical Limitations of Methods of Locating Subsurface Utilities: Ground Penetrating Radar (GPR) is a non-destructive geophysical method that uses radar pulses to image the subsurface. This technique uses electromagnetic radiation in the microwave band of the radio spectrum, and detects the reflected signals from subsurface structures. The working principle of GPR involves emitting a high-frequency radio wave into the ground and observing the reflected signals. The radar antenna emits the signal into the ground, and when the signal hits a boundary with different dielectric constants, the signal is reflected back to the antenna. The time it takes for the reflection to arrive back at the receiver is proportional to the depth of the object causing the reflection. The reflected signals are recorded by the system and then processed to create a subsurface profile. The resulting profile can be interpreted to understand the subsurface conditions, including the presence of buried objects or changes in material properties. Despite its extensive utility in geology, archaeology, surveying, and engineering, GPR does have some technical limitations. Understanding these limitations is critical. Soil and Material Properties: One of the primary limitations of GPR is the sensitivity to material properties. Conductive materials such as clay, salty water, or certain types of minerals can absorb and attenuate the radar signal, reducing the depth of penetration. Non-metallic materials and utilities may not reflect signals as strongly as metallic materials and utilities. Similarly, heterogeneous materials or conditions can cause signal scattering, which may complicate the interpretation of the results. Penetration Depth: While GPR can be incredibly useful for shallow investigations, the depth of penetration is limited. The penetration depth is determined by the frequency of the radar wave, with lower frequencies penetrating deeper but providing less resolution, and higher frequencies offering higher resolution but shallower penetration. Differentiation Between Similar Materials: GPR may struggle to differentiate between objects or layers of similar dielectric constants. This can lead to difficulties in DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4 2024 01-31 Proposal Project No. 03045.193 Page 3 of 8 distinguishing between different layers or objects within the subsurface, potentially causing inaccurate interpretations. Small Objects: GPR has limitations when detecting small objects. The minimum size of detectable objects is approximately equal to the wavelength of the radar wave, which means higher frequency (and thus, shorter wavelength) systems are required for detecting small objects, sacrificing depth penetration. Surface and Subsurface Conditions: Surface conditions such as rough terrain or vegetation can negatively impact GPR data quality. Similarly, certain subsurface conditions like soil moisture, temperature, and the presence of metallic objects can cause signal distortion or absorption. Electromagnetic Induction (EMI) systems are a common method for locating buried utilities due to their non-invasive nature and potential for high accuracy. EMI systems work by transmitting an electromagnetic field into the ground using a coil. When this field interacts with a buried utility, it induces electric currents within the utility, generating a secondary magnetic field. The EMI system's receiver detects this secondary field, and the difference between the primary and secondary fields is analyzed to determine the presence and approximate location of the utility. Depth limitation: The depth at which an EMI system can detect underground utilities is largely dependent on the frequency of the electromagnetic wave used. High-frequency signals can yield detailed information about shallow subsurface features but do not penetrate deeply into the ground. Conversely, low-frequency signals can reach greater depths but offer less precision. Soil conditions: Soil conditions can greatly affect the accuracy of an EMI system. For example, high moisture content or high conductivity soils can interfere with the magnetic field, making it difficult to accurately locate utilities. Similarly, rocky or sandy soils can scatter the magnetic field, leading to inaccuracies. Interference: When multiple utilities are present in the same location, the signals from each utility can interfere with each other, leading to inaccuracies. This is especially true when the utilities are close together, such as in congested urban areas. Non- conductive utilities: EMI systems are primarily designed to detect conductive utilities, such as metal pipes or cables. Non-conductive utilities, such as plastic pipes, may not be detectable by an EMI system. The final deliverable will be an electronically signed and sealed copy of the Topographic/Tree Survey and SUE Report with accompanying AutoCAD file, which can be provided within forty (40) business days of receiving authorization to proceed. In the event of rain delaying our field work, the delivery time will be pushed back the same number of days. Engineering Services Engenuity Group, Inc. will provide Civil Engineering Design & Plans, and permitting, Bid Assistance, Construction Phase Services and Geotechnical. Our services as set forth in Exhibit “A” will be providing for a lump sum of $50,400.00 based on the following distribution of compensation, with optional services totaling $23,100: DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4 2024 01-31 Proposal Project No. 03045.193 Page 4 of 8 A. Civil Engineering Design and Permitting $22,000.00 B. Utility Coordination $5,000.00 C. Public Information Section (3 public meetings) $3,800.00 D. Bid Assistance (OPTIONAL) $1,500.00 E. Construction Phase Services (OPTIONAL) $6,500.00 Subconsultant (Terracon) A. 12 soil borings (Excludes Maintenance of Traffic) $19,600.00 Additional Alternate (OPTIONAL): B. 8 soil borings with Maintenance of Traffic $15,600.00 This proposal is subject to the terms of the Continuing Contract for Engineering Services between Engenuity Group and the Village.” Permit Fees, Reproduction Charges and Reimbursable Expenses The Total Contract Price does not include the payment of any governmental agency submittal or processing fees. The cost of these fees and any costs incurred by the office for printing, reproduction and other reimbursable expenses such as postage, travel, and document copy charges will be billed to the client monthly. Invoicing and Payment Work will be invoiced on a monthly basis for work completed to date. Invoice shall be paid in full by the Client within thirty (30) days of the invoice date, unless within such thirty (30) day period, Client notifies Engenuity Group, Inc. in writing of its objection to the amount of said invoice. Such notice shall be accompanied by payment of any undisputed portion of said invoice. If written objection is not received within thirty (30) days it shall constitute approval of invoice by Client. If the payment is not received within fifteen (15) days of billing date, a late charge will be added to the invoice in the amount of 1½ percent per month on the outstanding balance. If payment is not received within sixty (60) days of the invoice date, work may be suspended on the project until the outstanding invoice(s) are paid in full. This proposal represents the entire understanding between you and us with respect to the Project. If this satisfactorily sets forth your understanding of our agreement, please execute the attached Authorization and return it to us. If you have any questions, please do not hesitate to contact us. PURSUANT TO SECTION 558.0035 FLORIDA STATUTES, THE CONSULTANT IS THE RESPONSIBLE PARTY FOR THE DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4 2024 01-31 Proposal Project No. 03045.193 Page 5 of 8 PROFESSIONAL SERVICES IT AGREES TO PROVIDE UNDER THIS CONTRACT. NO INDIVIDUAL PROFESSIONAL EMPLOYEE, AGENT, DIRECTOR, OFFICER OR PRINCIPAL MAY BE INDIVIDUALLY LIABLE FOR NEGLIGENCE ARISING OUT OF THIS CONTRACT, AS LONG AS THE CONSULTANT MAINTAINS THE PROFESSIONAL LIABILITY INSURANCE REQUIRED UNDER THIS CONTRACT AND AS LONG AS ANY DAMAGES ARE SOLELY ECONOMIC IN NATURE AND THE DAMAGES DO NOT EXTEND TO PERSONAL INJURIES OR PROPERTY NOT SUBJECT TO THIS CONTRACT. Sincerely, Approved by, Jennifer Malin, P.S.M. Adam Swaney, P.E. Director of Surveying Director of Engineering DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4 2024 01-31 Proposal Project No. 03045.193 Page 6 of 8 Authorization: Professional Civil Engineering & Surveying Services East Alley Wall Replacement North Palm Beach, Florida Engenuity Group, Inc. Project No. 03045.193 By: Date: Name & Title) For: Name of Company) Contract Amount: $99,744.00 Engineering: $50,400.00 Surveying: $16,420.00 SUE: $9,324.00 Optional: $23,600.00 I am I am not The Owner of the Property The Property Owner Is: Address: Email: Telephone: Fax: DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4 chuff@village-npb.org yyyyyy yyyyyy 561904212 North Palm Beach, FL 33408 NPB 4/2/2024 561-904-2122 Village manager Village of North Palm Beach 501 US Hwy One nnnnnn nnnn 2024 01-31 Proposal Project No. 03045.193 Page 7 of 8 DESIGNATED SCOPE OF SERVICES: TOPOGRAPHIC/TREE SURVEY NAME: EAST ALLEY WALL REPLACEMENT ENGENUITY PROJECT NO. 03045.193 DATE: 3/7/2024 TASK: Topographical Survey Included in Contract Yes/No) Minimum of two permanent benchmarks per every 500’ on site; description and elevation to nearest .01’. Yes Contours at 1-foot intervals; error shall not exceed one half contour interval. No Spot elevation at each intersection of a 50-foot square grid covering the property. Yes Spot elevations at street intersection and at 100 feet on center curb, sidewalk and edge of paving including far side of paving. Yes Topographic data will be obtained at 100-foot intervals of the road from right-of-way to right-of-way. Yes Plotted location of structures, man-made (e.g., paved areas) and natural features. Yes Location of water mains, and other utilities including, but not limited to, buried tanks and septic fields serving, or on, the property based on as-built information supplied by utility companies. Yes Location of fire hydrants available to the property. Yes Location and characteristics of power and communications systems above grade. Yes Location, size, depth and direction of flow of sanitary sewers, storm drains and culverts serving, or on, the property; location of catch basins and manholes, and inverts of pipe at each. Yes Name of the operating authority of each utility. No Elevation of water in any excavation, well or nearby body of water. No Extent of watershed onto the property. No Trees of 6” and over (caliper 3’ above ground); locate within 1’ tolerance and give species in English or botanical terms. Yes Specimen trees flagged by the Owner or the Architect (___ in number); locate to the center within 1’ tolerance; give species in English or botanical terms, give caliper and ground elevation on upper slope side. No Perimeter outline only of thickly wooded areas unless otherwise directed. Yes Confirm soil boring location(s). No SUE Services included in the scope Yes Scale of drawing is typically 1”=20’ but will be determined by Engenuity Group, Inc. unless the client specifies a scale they would like the drawing at. Other (specify): 1. Datum will be National American Vertical Datum 1988 (NAVD 88) 2. SUE Services are included in the services DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4 2024 01-31 Proposal Project No. 03045.193 Page 8 of 8 Graphic DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4 EXHIBIT “A” – ENGINEER’S SERVICES PAGE 1 OF 4 2023 12-11 Revised 2024 01-24 Project No. 03045.193 EXHIBIT “A” East Alley Wall Replacement North Palm Beach, FL Engenuity Group Project No. 03045.193 ENGINEER’S SERVICES: A1.01 Construction Documents Scope of work: 1. Provide civil engineering design for a replacement wall along the east alleyway Approximately 4,000 LF). The proposed wall shall match as close as possible the height, architectural style, and color scheme of the existing East Alley Wall located between Ebbtide Dr. and Anchorage Dr. S. 2. Prepare final drawings indicating the scope, extent, and character of the wall, paving, and restoration work to be performed and furnished by the CONTRACTOR. 3. Prepare a Stormwater Pollution Prevention Plan. 4. Prepare Engineer’s Opinion of Cost for the overall civil site improvements, including itemized pay-item and quantities. 5. The public information scope includes attending up to three (3) public meetings and display materials. Meeting summaries/minutes will be provided with the feedback collected to present to staff for decision making purposes. 6. Provide utility coordination and plan depiction via Sunshine State One Call. Two overhead poles are located in conflict with the wall. Engenuity will provide coordination with FPL (or ATT if they are the owner of the poles) to coordinate removal and undergrounding if possible. 7. Prepare specifications in general conformance with the 16 Division format of the Construction Specifications Institute. These may provide within the construction plans in a notes section. 8. Soil borings and analysis. (subconsultant) A1.03 Bidding Phase Services (OPTIONAL) A. Assist OWNER in advertising for and obtaining bids for the Work. B. Attend pre-bid conference and issue minutes. DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4 EXHIBIT “A” – ENGINEER’S SERVICES PAGE 2 OF 4 2023 12-11 Revised 2024 01-24 Project No. 03045.193 C. Issue Addenda as appropriate to clarify, correct, or change the Bidding Documents. D. Attend the Bid opening, prepare Bid tabulation sheets, evaluate Bids and make a recommendation for award. E. Perform cursory review of signed contracts, bonds, and insurance certificates received from CONTRACTOR and transmit to OWNER for signing of contracts. A1.04 Construction Phase Services (OPTIONAL) A. Preconstruction Conference. Attend a Preconstruction Conference prior to commencement of Work at the Site. B. Visits to Site and Observation of Construction. In connection with observations of CONTRACTOR’S work in progress while it is in progress: 1. Make no more than 8 visits to the site at intervals appropriate to the various stages of construction, as ENGINEER deems necessary, in order to observe as an experienced and qualified design professional the progress and quality of the Work. Such visits and observations by ENGINEER, are not intended to be exhaustive or to extend to every aspect of CONTRACTOR’S work in progress or to involve detailed inspections of CONTRACTOR’S work in progress beyond the responsibilities specifically assigned to ENGINEER in the Contract Documents, but rather are to be limited to spot checking, selective sampling, and similar methods of general observation of the Work based on ENGINEER’S exercise of professional judgment. Based on information obtained during such visits and such observations, ENGINEER will determine in general if CONTRACTOR’S work is proceeding in accordance with the Contract documents, and ENGINEER shall keep OWNER informed of the progress of the Work. 2. ENGINEER will not, during such visits or as a result of such observations of CONTRACTOR’S work in progress, supervise, direct, or have control over CONTRACTOR’S work nor shall ENGINEER have authority over or responsibility for the means, methods, techniques, sequences, or procedures of construction selected by CONTRACTOR, for safety precautions and programs incident to regulations applicable to CONTRACTOR’S furnishing and performing the Work. Accordingly, ENGINEER neither guarantees the DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4 EXHIBIT “A” – ENGINEER’S SERVICES PAGE 3 OF 4 2023 12-11 Revised 2024 01-24 Project No. 03045.193 performance of any CONTRACTOR nor assumes responsibility for any CONTRACTOR’S failure to furnish and perform its work in accordance with the Contract Documents. C. Clarifications and Interpretations; Field Orders. Issue necessary clarifications and interpretations of the Contract Documents as appropriate to the orderly completion of CONTRACTOR’S work. Such clarifications and interpretations will be consistent with the intent of and reasonably inferable from the Contract Documents. ENGINEER may issue Field Orders authorizing minor variations from the requirements of the Contract Documents. D. Shop Drawings and Samples. Review and approve or take other appropriate action in respect to Shop Drawings and Samples and other data which CONTRACTOR is required to submit, but only for conformance with the information given in the Contract Documents and compatibility with the design concept of the completed Project as a functioning whole as indicated in the Contract Documents. Such review and approvals or other action will not extend to means, methods, techniques, sequences or procedures of construction or to safety precautions and programs incident thereto. ENGINEER has an obligation to meet the CONTRACTOR’S submittal schedule that has earlier been acceptable to ENGINEER. E. Applications for Payment. Based on ENGINEER’S on-site observations as an experienced and qualified design professional, ENGINEER will review pay applications and advise OWNER to either recommend payment or return the pay application to the CONTRACTOR for correction. F. Inspections and Tests. Require such special inspections or tests of CONTRACTOR’S work as deemed reasonably necessary, and receive and review all certificates of inspections, tests, and approvals required by Laws and Regulations or the Contract Documents. ENGINEER’S review of such certificates will be for the purpose of determining that the results certified indicate compliance with the Contract Documents and will not constitute an independent evaluation that the content or procedures of such inspections, tests, or approvals comply with the requirements of the Contract Documents. ENGINEER shall be entitled to rely on the results of such tests. Field testing of materials is not included in ENGINEER’S scope of services. G. Record Drawings. Review Record Drawings prepared and certified by the CONTRACTOR’S Florida licensed surveyor and the CONTRACTOR. H. Completion of Construction Certifications. Prepare construction completion certifications and submit to the following agencies: DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4 EXHIBIT “A” – ENGINEER’S SERVICES PAGE 4 OF 4 2023 12-11 Revised 2024 01-24 Project No. 03045.193 1. Village of North Palm Beach I. Substantial Completion. Promptly after notice from CONTRACTOR that CONTRACTOR considers the entire Work ready for its intended use, in company with OWNER and CONTRACTOR, conduct a review of the work to determine if it is Substantially Complete. J. Final Notice of Acceptability of the Work. Conduct a final review to determine if the completed Work of CONTRACTOR is acceptable. K. Contract Time. ENGINEER’S services during construction are dependent upon the timely performance of CONTRACTOR’S work. ENGINEER’S services are based on a construction Contract Time of 180 calendar days for final completion of the work. If the CONTRACTOR exceeds such period of time, ENGINEER’S compensation shall be subject to an equitable adjustment. A1.05 This proposal does not include the following: A. The design of any major off-site roadway improvements. B. Reproduction of drawings and specifications for CONTRACTOR’S use during construction. C. Construction layout survey or record drawings. D. Design of landscaping, irrigation, and lighting. E. Coordination of new or relocated electrical, gas, telephone, and TV services. F. Environmental Analysis or design including wetlands, uplands, or contamination. DocuSign Envelope ID: 0963AF91-09E3-4647-9494-E70ED512DCD4